GCL-300f Ultrasonic Sludge Interface Meter
+
  • GCL-300f Ultrasonic Sludge Interface Meter

Share to

GCL-300f Ultrasonic Sludge Interface Meter

The GCL-300F Ultrasonic Sludge Interface Meter is a device used for real-time detection of sludge thickness. Utilizing the reliable principle of ultrasonic echo detection, the ultrasonic sludge interface meter achieves real-time detection of sludge thickness, providing reliable data for process control of relevant processes, thereby optimizing the process control of sludge discharge and chemical addition.

Customer Service:

Category:

Measurement Devices

Keywords:

Product Details

The GCL-300F Ultrasonic Sludge Interface Meter is a device used for real-time detection of sludge thickness. Utilizing reliable ultrasonic echo detection principles, the ultrasonic sludge interface meter achieves real-time sludge thickness detection, providing reliable data for process control in related processes, thereby optimizing sludge discharge and chemical dosing process control flows.

 

Features

  • Continuous measurement, low maintenance
  • Ultrasonic high-frequency technology, stable and reliable performance
  • Chinese menu, easy to operate
  • Multiple interface outputs such as 4~20mA current and relay, system integrated control
  • Automatically adjusts the transmission power according to the mud layer
  • Advanced digital model calculation, anti-interference design

 

Application Areas

  • Water plant sedimentation tanks
  • Sedimentation tanks in mining and washing plants
  • Power plant slurry sedimentation tanks
  • Primary sedimentation tanks, secondary sedimentation tanks, and thickening tanks in wastewater treatment plants

 

Main Technical Indicators

Technical Indicators

Measurement Range

0.5~12m

Measurement Accuracy

±1.0%Fs

Measurement Resolution

1mm

Repeatable Accuracy Performance

±1.0%Fs

Power Consumption

≤15W

Supply Voltage

DC12V、DC24V、AC220V (Standard)

Output

4~20mA, 750Ω load

Switch Output

2-channel relay (220VAC/5A)

Instrument Display

LCD liquid crystal display

Medium Temperature

Sensor -20~60℃

Medium Pressure

≤10ba

Sensor Material

316 stainless steel (standard), PVC

Signal Cable

Standard 10M (can be extended)

Installation Method

Immersion

Protection Level