Product Center
Dedicated to the Research and Application of Sensor Technology, Microelectronics Technology, Internet of Things Technology, and other related fields.

Product Center

Contact Us

Mobile: Mr. Zhou +86-18900715600

Telephone: +86-731-88238888

Hotline: +86-400 0586 896

Email: hzgc@cshnac.com

Address: No. 609, Lusong Road, Lugu, High-tech Zone, Changsha, Hunan Province, China

GCL-600 Radar Flowmeter
+
  • GCL-600 Radar Flowmeter

Share to

GCL-600 Radar Flowmeter

The GCL-600 is a fully automatic flow meter based on microwave technology. It uses advanced K-band planar radar technology to measure the flow velocity and water level of water bodies in a non-contact manner. Based on the built-in software model and algorithm, it calculates and outputs the real-time instantaneous flow rate and cumulative flow rate; it can be used for non-contact flow measurement in rivers, canals, underground drainage networks, flood warning, etc.; the product has the characteristics of low power consumption, high reliability, and easy maintenance; the measurement process is not affected by factors such as temperature, sediment, river pollutants, and floating objects on the water surface.

Customer Service:

Category:

Measurement Devices

Keywords:

Product Details

The GCL-600 is a fully automatic flow meter based on microwave technology. It uses advanced K-band planar radar technology to non-contactly measure the flow velocity and water level of a water body. Based on the built-in software model and algorithm, it calculates and outputs the real-time instantaneous flow rate and cumulative flow rate; it can be used for non-contact flow measurement in rivers, canals, underground drainage networks, flood prevention and early warning, etc.; this product features low power consumption, high reliability, and easy maintenance; the measurement process is not affected by factors such as temperature, sediment, river pollutants, and floating objects on the water surface.

 

Features

o Non-contact measurement, combined with cross-sectional parameters to calculate flow rate, unaffected by wind, temperature, haze, sediment, or floating objects. Features a rainproof mode.

o Suitable for various measurement conditions, it can output flow velocity, water level, and flow rate measurement data.

o Expandable array-type multi-point flow measurement, configuring one flow meter and multiple flow meters, through the flow meter's internal algorithm fitting, to achieve flow measurement of wide cross-sections.

o Suitable for trapezoidal, circular, U-shaped, and other cross-sections; cross-sectional parameter setting is simple and convenient.

o Convenient configuration software allows for easy parameter configuration according to actual needs to adapt to different usage conditions.

 

Application Areas

o Flow velocity, water level, or flow rate measurement in rivers, lakes, tides, reservoir gates, ecological discharge, underground pipelines, and canals.

o Assisting water treatment operations, such as municipal water supply and sewage monitoring.

o Flow calculation, inflow and outflow monitoring, etc.

 

Main Technical Indicators

Flow Measurement System

Measurement Principle

Planar microstrip array antenna CW+FMCW

Operating Mode

Manual, Automatic, Remote Sensing

Applicable Environment

24 hours, Rainy Days

Operating Voltage

7~32VDC/5.5~32VDC (optional)

Operating Current

12VDC input, operating mode: ≤120mA standby mode: ≤1mA

sVr-24CQsZ-r (4G operating current ≤80mA; NB-IoT operating current ≤30mA; sleep ≤30UA)

Radar Velocity Sensor

Radar Frequency

24GHz

Maximum Measuring Range

40m

Velocity Measurement Range

0.03~20m/s

Velocity Measurement Accuracy

±0.01m/s; ±1%Fs

Antenna Angle

12°

Measurement Direction

Automatically identifies water flow direction, built-in vertical angle correction

Radar Water Level Sensor

Radar Frequency

24GHz

Measurement Range

0.2-40 meters

Measurement Accuracy

±3mm, ±6mm

Antenna Angle

11

Wireless Configuration

Bluetooth

Data Transmission System

Data Transmission Method

rs485/rs232, 4~20mA, Lora (wireless optional), NB-IoT, 4G

Other Parameters

Operating Temperature

-30℃~80℃

Storage Temperature

-40℃~70℃

Protection Level

lp68

Lightning Protection Level

6KV

Dimensions

235.4×100×103.7 (mm)

Weight

Less than 1.5kg