GCL-200 (60g) Radar Water (Liquid) Level Gauge
Category:
Measurement Devices
Keywords:
Product Details
The GCL-200 (60G) series radar water level gauge uses 60GHz electromagnetic waves to measure water levels. It is a non-contact measurement device mainly used for measuring water levels in rivers, lakes, reservoirs, channels, and sewage networks, providing real-time water level data to relevant units.
Technical Advantages
- Non-contact, safe and low-loss, low maintenance, unaffected by silt, etc.
- High-precision measurement with millimeter accuracy, ultra-low blind zone
- The power supply circuit adopts reverse connection and lightning protection design.
- Low system power consumption; solar power is generally sufficient for measurement needs.
- Built-in angle and attitude sensor to detect installation tilt for easy installation and debugging.
- Multiple interface options, including digital and analog interfaces, for easy integration into various systems.
- Easy installation, no mechanical wear, very few failures during use, and long service life.
- Fully waterproof design, suitable for outdoor use.
Application Areas
- Water level/flow monitoring in water conservancy, agriculture, and irrigation areas.
- Water level/flow monitoring in the petroleum, chemical, and metallurgical industries.
- Water level monitoring for urban flood control, waterlogging, underground pipelines, and manholes.
Main Technical Indicators
Serial Number |
Parameter |
Range |
Remarks |
1 |
Frequency |
60GHz |
|
2 |
Beam Angle |
10° |
|
3 |
Antenna |
Planar microstrip pulse coherent radar |
|
4 |
Measuring Range |
12m |
|
5 |
Blind Zone |
0.25m |
|
6 |
Measurement Accuracy |
±2mm |
|
7 |
Resolution |
1mm |
|
8 |
Operating Voltage |
DC9~28V |
24VDC power supply is used for models with analog output function. |
9 |
Average Power Consumption |
≤7.5mA, sleep ≤1mA@DC12V |
|
10 |
Communication Method |
rs485 (Modbus protocol), 4-20mA, 4G, NB, Lora |
Customizable protocol |
11 |
Operating Temperature |
-35℃~+70℃ |
|
12 |
Protection Level |
lp68 |
|
13 |
Weight |
Approximately 1±0.05kg |
|
14 |
Dimensions |
120×110×108(mm) |
Excluding battery box and antenna |