GCF-M Series Open Channel Flow Meter
Category:
Measurement Devices
Keywords:
Product Details
The GCF-M series ultrasonic time-difference open channel flow meter is a high-performance ultrasonic flow meter independently designed and developed by our company. Based on the time-difference measurement principle and using an open structure, this flow meter is suitable for accurate flow measurement in main and branch streams of water conservancy and irrigation areas.
The product includes an ultrasonic flow measurement unit and a radar level unit. By using layered velocity and level data, it accurately measures water flow. The product can also easily connect to RTUs, lithium batteries, solar chargers, etc., to achieve storage and real-time upload of water level and flow data. The product has high measurement accuracy, high reliability, and simple maintenance.
Features
- Wide measurement range: Measurable range of ±0.01m/s-±5m/s
- Reliable transducer structure: Smooth water flow, not easy to accumulate debris, reliably withstands floods to avoid damage
- High stability: Integrated data processing algorithm, water flow state, impurities, and accumulation have no effect on the results
- Strong scalability: Connecting RTU, lithium battery, and solar charger for convenient power supply and real-time data upload
- Industrial-grade reliability: Key components use high-performance, high-reliability industrial components for a long service life
- Accurate measurement: Low-noise measurement circuit combined with flow state fitting algorithm, measurement error within the full range is less than the standard requirement
- Easy installation: Customized production according to the site environment, on-site calibration-free, no wiring required, configuration can be completed via mobile phone Bluetooth
- Simple equipment maintenance: Supports remote status detection, equipment upgrades, and fault diagnosis; it can also be maintained via on-site Bluetooth connection
Application Areas
- Open channel and gate flow measurement and monitoring in water conservancy, agriculture, and irrigation areas
- Flow measurement and monitoring of urban drainage
Model Specifications
Model |
Width (Inner diameter) (mm) |
Height (Inner diameter) (mm) |
Length ( mm ) |
Minimum effective liquid level (mm) |
Minimum flow (m3/s) |
Maximum flow (m3/s) |
Number of transducers |
GCF-MA04 |
400 |
400 |
500 |
50 |
0.00024 |
0.8 |
8 |
GCF-MA06 |
600 |
600 |
600 |
50 |
0.00036 |
1.8 |
12 |
GCF-MA08 |
800 |
800 |
700 |
50 |
0.00048 |
3.2 |
16 |
GCF-MA10 |
1000 |
1000 |
700 |
50 |
0.0006 |
5.0 |
20 |
GCF-MA12 |
1200 |
1200 |
700 |
50 |
0.00072 |
7.2 |
24 |
Other models can be customized |
Main Technical Indicators
Item |
Indicator |
Flow Measurement System |
|
Velocity measurement range |
±0.01 m/s~±5m/s |
Number of flow measurement layers |
8 layers~24 layers, more layers can be customized |
Measurement error (GB/T 11826.2-2012) |
≤0.1m/s error ±0.008m/s |
0.1-5m/s: error ±2.5% |
|
Measurement resolution |
0.001m/s (flow velocity) |
Level System |
|
Level detection range |
0-400mm~1200mm |
Level detection accuracy |
±2mm |
Data Transmission System |
|
Data transmission method |
rs485 (MODBUs protocol) |
Other |
|
Temperature detection range |
-10~60℃(GB/T 15966-2017) |
Electromagnetic interference resistance |
Meets GB/T 11826.2-20126.2.4 |
Water temperature detection accuracy |
No more than ±0.2℃(GB/T 15966-2017) |
Operating temperature |
-25℃-55℃(GB/T 11826.2-2012 requirement) |
Storage temperature |
-40℃~60℃, relative humidity no more than 85% (GB/T 11826.2-2012) |
Operating voltage |
7-32VDC; |
Operating current |
7-32VDC, average current <20mA, peak current <200mA |
Insulation |
No less than 5MΩ between sensor power supply and housing (GB/T 15966-2017) |
Protection level |
lp68 |
Lightning protection |
Lightning protection level 6KV |
Product implementation standards |
GB/T 11826.2-2012 Velocity and flow rate instruments |
GB/T 15966-2017 Basic parameters and general technical conditions of hydrological instruments |